Objective: To appraise the available evidence for patient monitoring, perioperative active warming methods, outcomes supporting the prevention of perioperative hypothermia, and implementation strategies for the prevention of perioperative hypothermia. Outcomes: Outcomes assessed included the precision and accuracy of thermometers, efficacy of warming devices including IV fluid warmers and forced-air devices, and surgical site infections and morbid cardiac events associated with PH. Evidence: MEDLINE, EMBASE, and the Cochrane Database were searched to identify randomized controlled trials of efficacy and prospective studies of diagnostic accuracy. Two authors reviewed the abstracts to identify articles for critical appraisal. The methods of the Canadian Task Force on Preventive Health Care were employed to grade study quality and level of evidence, as well as formulate the final recommendations. Recommendations: The evidence supports the use of esophageal temperature probes for temperature monitoring in all patients undergoing abdominal surgery while under general anaesthetic; awake patients and patients in recovery should have temperatures monitored using