The determination of the amorphous phase content is a key problem of ceramic science, in particular for silicate ceramics and refractories. Rietveld-based quantitative phase analysis using XRD with internal standard / IS is suitable for this purpose, but absorption issues complicate the task when “xeno-phase” standards like zincite are used. In this paper, taking model powder mixtures of corundum, quartz, and amorphous silica as paradigmatic examples, it is shown that reliable results can be obtained by the “amorphous minimum estimate” / AME, a simple standard-free multimethod approach based on both XRF and XRD. The AME approach tends to fail only for systems containing a high content of crystalline silica (quartz) alongside with a low content of amorphous silica. In this case, the best results are achieved via the IS method using an “iso-phase” standard like corundum in combination with an independent XRD measurement of a standard-free sample (“external reference” approach).
No takes yet. Share an insight, caveat, or question.
Pabst et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: