Why the study?
It was unknown whether multidimensional measurement of breathlessness is useful to differentiate individuals with abnormal versus normal exertional breathlessness intensity.
Does the multidimensional dyspnea profile differentiate between outpatients with abnormal versus normal exertional breathlessness intensity during an incremental exercise test?
Does the multidimensional dyspnea profile differentiate between outpatients with abnormal versus normal exertional breathlessness intensity during an incremental exercise test?
Multidimensional breathlessness dimensions measured at peak exercise do not differentiate between patients with normal versus abnormally high exertional breathlessness.
Answers are grounded in this paper and cite their sources.
Peak-exercise MDP ratings do not differentiate exertional breathlessness severity in outpatients; leaves open its clinical utility and requires prospective validation.
BACKGROUND/AIM: Exertional breathlessness is a dominating symptom in cardiorespiratory disease, limiting exercise capacity. Multidimensional measurement has been proposed to capture breathlessness, but it is unknown whether it is useful to differentiate people with abnormal vs normal exertional breathlessness intensity. METHODS: This was a secondary analysis of a randomized controlled trial of outpatients aged ≥ 18 years performing a symptom-limited cycle incremental exercise test (IET). Breathlessness sensations at end of IET were identified using the multidimensional dyspnea profile (MDP) 30-min post-exercise and compared between people with abnormally high breathlessness (Borg 0-10 rating > upper limit of normal [ULN]) and people within normal ranges (≤ ULN) in relation to the percentage of predicted peak power output defined by normative reference equations. RESULTS: Of 92 participants, 20 (22 %) had abnormally high breathlessness. Compared with those with normal breathlessness (n = 72 [78 %]), the abnormal group reported higher symptom intensity at peak exercise (7.9 ± 1.7 vs 6.3 ± 1.4 Borg units; p < 0.001) and had lower peak power output 129 ± 52 W vs 167 ± 55 W; p < 0.001). Differences between those with normal, and abnormal exertional breathlessness regarding MDP ratings were not statistically significant (all p > 0.05): overall unpleasantness, 4.1 ± 2.3 vs 4.7 ± 1.6; immediate perception, 10.9 ± 2.8 vs 11.5 ± 1.8; and emotional response, 4.1 ± 7.6 vs 3.2 ± 7.5. MDP ratings had no relation to peak power output. CONCLUSION: Breathlessness dimensions are similar at the peak of a standardized IET and cannot differentiate between people with normal and abnormally high exertional breathlessness.