Answers are grounded in this paper and cite their sources.
AIM: Positron emission tomography (PET) imaging is a useful tool for assisting in correct differentiation of tumor progression from reactive changes, and the radiolabeled amino acid analogue tracer O-(2-18F-fluoroethyl)-L-tyrosine (FET)-PET is amongst the most frequently used. The FET-PET images need to be quantitatively correct in order to be used clinically, which require accurate attenuation correction (AC) in PET/MRI. The aim of this study was to evaluate the use of the subject-specific MR-derived AC method RESOLUTE in post-operative brain tumor patients. METHODS: We analyzed 51 post-operative brain tumor patients (68 examinations, 200 MBq [18F]-FET) investigated in a PET/MRI scanner. MR-AC maps were acquired using: 1) the Dixon water fat separation sequence, 2) the ultra short echo time (UTE) sequences, 3) calculated using our new RESOLUTE methodology, and 4) a same day low-dose CT used as reference “gold standard”. For each subject and each AC method the tumor was delineated by isocontouring tracer uptake above a tumor(T)-to-brain background(B) activity ratio of 1.6. We measured B, tumor mean and maximal activity (TMEAN, TMAX), biological tumor volume (BTV), and calculated the clinical metrics TMEAN/B and TMAX/B. RESULTS: When using RESOLUTE 5/68 studies did not meet our predefined acceptance criteria of TMAX/B difference to CT-AC < +/-0.1 or 5%, TMEAN/B < +/-0.05 or 5%, and BTV < +/-2 mL or 10%. In total, 46/68 studies failed our acceptance criteria using Dixon, and 26/68 using UTE. The 95% limits of agreement for TMAX/B was for RESOLUTE (-3%;4%), Dixon (-9%;16%) and UTE (-7%;10%). The absolute error when measuring BTV was 0.7+/-1.9 mL (N.S) with RESOLUTE, 5.3+/-10 mL using Dixon, and 1.7+/-3.7 mL using UTE. RESOLUTE performed best in the identification of the location of peak activity and in brain tumor follow-up monitoring using clinical FET PET metrics. CONCLUSIONS: Overall, we found RESOLUTE to be the AC method that most robustly reproduced the CT-AC clinical metrics per se, during follow-up, and when interpreted into defined clinical use cut-off criteria and into the patient history. RESOLUTE is especially suitable for brain tumor patients, as these often present with distorted anatomy where other methods based on atlas/template information might fail.
No takes yet. Share an insight, caveat, or question.
Ladefoged et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: