Why the study?
Does intracardiac echocardiography (ICE) guidance improve safety and reduce radiation exposure compared to transesophageal echocardiography (TEE) in patients undergoing device closure of interatrial communications?
Does intracardiac echocardiography (ICE) guidance improve safety and reduce radiation exposure compared to transesophageal echocardiography (TEE) in patients undergoing device closure of interatrial communications?
ICE guidance for device closure of interatrial communications is safe, avoids the need for sedation or anesthesia, and significantly reduces fluoroscopy and procedure times compared to TEE.
Answers are grounded in this paper and cite their sources.
ICE may limit radiation in interatrial closure; leaves open randomized safety comparisons versus TEE.
BACKGROUND: This study sought to evaluate safety and radiation exposure when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) in order to guide transcatheter closure of interatrial communications. METHODS: Eighty patients (44 males, 36 females, mean age 46, SD 13 years) undergoing device closure of atrial septal defect (n=12) or patent foramen ovale (n=68) had the procedure guided by ICE (n=50, group 1) or TEE (n=30, group 2). In group 1, all procedural stages were completely guided by ICE, including imaging of the interatrial communication during balloon sizing, device unfolding and release, and during the final check for adequate positioning. In group 2, exclusive implantation of devices was guided by use of TEE. RESULTS: Especially, the spatial relationship between device and cardiac structures (e.g. the ascending aorta, the interatrial septum and the superior vena cava) was accurately demonstrated in group 1. Image resolution provided by ICE was superior to that of TEE. No severe complications, including any related to ICE, were seen. Fluoroscopy time (FT) and procedure time (PT) were shorter in group 1 than in group 2 (FT: 5.5+/-1.5 min vs. 9.3+/-1.6 min, P<0.0001; PT: 31.9+/-4.6 min vs. 38.8+/-5.8 min, P<0.01). Neither sedation nor anesthesia was required in group 1. CONCLUSIONS: ICE is a safe tool to guide device closure of interatrial communications. For the patient, procedural stress and radiation exposure are negligible. ICE can be considered the guiding tool of choice for device closure, particularly when long or repeated echocardiographic viewing is required.
No takes yet. Share an insight, caveat, or question.
Bartel et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: