Why the study?
Most recent CIEDs can safely undergo CMR under certain conditions, but metal artifacts may degrade image quality.
Does cardiovascular magnetic resonance (CMR) provide good diagnostic yield and safety in patients with MR-conditional cardiac implantable electronic devices (CIEDs)?
Does cardiovascular magnetic resonance (CMR) provide good diagnostic yield and safety in patients with MR-conditional cardiac implantable electronic devices (CIEDs)?
CMR is safe and provides overall good image quality in patients with MR-conditional CIEDs, though ICDs induce more artifacts than pacemakers or loop recorders.
I have the paper; next I’ll pull the full results and conclusions so the implication tracks the primary endpoint.May support indicated CMR in MR-conditional CIEDs; confirms multicenter safety and extends prior single-center diagnostic-yield data.
BACKGROUND: Most recent cardiac implantable electronic devices (CIEDs) can safely undergo a cardiovascular magnetic resonance (CMR) scan under certain conditions, but metal artifacts may degrade image quality. The aim of this study was to assess the overall diagnostic yield of CMR and the extent of metal artifacts in a multicenter, multivendor study on CIED patients referred for CMR. METHODS: = 122), defibrillator (n = 149), or loop recorder (n = 38); CMR scans were performed in 10 centers from 2012 to 2020; MR-unsafe implants were excluded. Clinical and device parameters were recorded before and after the CMR scan. A visual analysis of metal artifacts was performed for each sequence on a segmental basis, based on a 5-point artifact score. RESULTS: The vast majority of CMR scans (n = 255, 83%) were completely performed, while only 32 (10%) were interrupted soon after the first sequences and 22 (7%) were only partly acquired; CMR quality was non-diagnostic in 34 (11%) scans, poor (<1/3 sequences were diagnostic) in 25 (8%), or acceptable (1/3 to 2/3 sequences were diagnostic) in 40 (13%), while most scans (n = 201, 68%) were of overall good quality. No adverse event or device malfunctioning occurred, and only nonsignificant changes in device parameters were recorded. The most affected sequences were SSFP (median score 0.32 [interquartile range 0.07-0.91]), followed by GRE (0.18 [0.02-0.59]) and LGE (0.14 [0.02-0.55]). ICDs induced more artifacts (median score in SSFP images 0.87 [0.50-1.46]) than PMs (0.11 [0.03-0.28]) or ILRs (0.11 [0.00-0.56]). Moreover, most artifacts were located in the anterior, anteroseptal, anterolateral, and apical segments of the LV and in the outflow tract of the RV. CONCLUSIONS: CMR is a versatile imaging technique, with a high safety profile and overall good image quality even in patients with MR-conditional CIEDs. Several strategies are now available to optimize image quality, substantially enhancing overall diagnostic yield.
No takes yet. Share an insight, caveat, or question.
Barison et al. (2023) studied this question.