Answers are grounded in this paper and cite their sources.
Specimens of four non-precious dental casting alloys intended for use in the ceramic-metal technique were implanted subcutaneously in the neck region of mice. The animals were killed after 5 months. Organs and tissues were tested as regards the concentration of nickel by means of atomic absorption spectrophotometry. The study showed that due to electrochemical corrosion nickel was released from implants and accumulated in some tissues and organs.
No takes yet. Share an insight, caveat, or question.
Bergman et al. (1980) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: