Answers are grounded in this paper and cite their sources.
This paper presents generalized techniques for realizing PWM patterns which provide selective harmonic elimination and current magnitude modulation (SHEM) for current source inverters/power converters (CSI/C). A combination of chops and short circuit pulses are positioned in such a way that lower order harmonics are eliminated selectively besides current magnitude modulation with minimum switching frequency. Generalized equations and tables which show the relationship of various PWM-SHEM parameters to the position of short circuit pulses and the number of chops per 30/spl deg/ are provided and discussed in detail.>
No takes yet. Share an insight, caveat, or question.
Karshenas et al. (1995) studied this question.