Does carbon-12 ion beam particle therapy induce atrioventricular node ablation in Langendorff-perfused porcine hearts?
Does carbon-12 ion beam particle therapy induce atrioventricular node ablation in Langendorff-perfused porcine hearts?
Carbon-12 ion beam therapy is a feasible catheter-free method for atrioventricular node ablation in an ex vivo porcine model.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for catheter-free AV node ablation; leaves open in vivo translation and clinical safety.
BACKGROUND: Particle therapy, with heavy ions such as carbon-12 ((12)C), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned 12C beam. METHODS AND RESULTS: Intact hearts were explanted from 4 (30-40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomographic scans (1 mm voxel and slice spacing) were acquired and (12)C ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomographic scans for detection of β(+) ((11)C) activity were obtained. A (12)C beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomography demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong γH2AX signals in the target region, whereas no γH2AX signals were detected in the unirradiated control heart. CONCLUSIONS: This is the first report of the application of a (12)C beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using 12C beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.
No takes yet. Share an insight, caveat, or question.
Lehmann et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: