Electron traps at the nanostructured TiO 2 (anatase)/aqueous electrolyte interface have been studied by means of electrochemical methods. The transient current decays at different potentials positive of the flat band potential clearly illustrate the trap-filling process. The more negative the potential, the shorter the trap-filling period. It is found that most traps locate positive of −0.9 V vs Ag/AgCl at pH 13, or positive of −0.3 V vs Ag/AgCl at pH 4.7. It is proposed that the trap distribution as a function of potential is directly proportional to d Q /d U, i.e., to the current density in a linear sweep voltammetry experiment. The trap densities in aqueous electrolytes are estimated to be 4 × 10 11 cm -2 (microscopic area) at pH 4.7 and 5 × 10 13 cm -2 (microscopic area) at pH 13. The pH dependency of the trap density indicates that traps investigated are surface-related.