The authors propose a novel dc voltage charge balance control for cascaded inverters. The proposed controller has two auxiliary control signal features: (1) a balanced discharging of isolated input dc voltages and (2) good flexibility and suitability for the applications when the number of H-bridge inverter modules is changed. When compared with the conventional cascaded inverters, the proposed control can self-adjust to achieve balance charge control without a complex circuit. The system does not require a new design of controller if a new H-bridge inverter module is added to the system for increasing the power capacity, or an H-bridge inverter module is disconnected from the system owing to its failure. The design of the auxiliary control signals is described in detail and implemented in software. Finally, a 7-level cascaded inverter with three dc–ac converter modules was constructed and tested. Analysis, simulations and experimental results are presented to demonstrate the superiority of the proposed system.
No takes yet. Share an insight, caveat, or question.
Hua et al. (2009) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More from IET Power Electronics