Why the study?
The study aimed to evaluate whether the Hypotension Prediction Index can detect a 5% volume deficit and whether this deficit is associated with decreased gastrointestinal microvascular flow.
Does the Hypotension Prediction Index detect a 5% volume deficit and correlate with decreased gastrointestinal microvascular flow in a porcine hemorrhage model?
Does the Hypotension Prediction Index detect a 5% volume deficit and correlate with decreased gastrointestinal microvascular flow in a porcine hemorrhage model?
In a porcine model, the Hypotension Prediction Index accurately detects a 5% blood volume loss, which corresponds to a significant disruption in intestinal microcirculation.
This is the authors' abstract. We don't add key points for this paper.
Background: Postoperative gastrointestinal (GI) dysfunction is a common complication following critical illness. The splanchnic circulation is sensitive to changes in volume status and is unduly impacted by volume loss compared to other organ systems. A raised Hypotension Prediction Index (HPI) value has been associated with decreased GI microcirculation flow in hemorrhage models at 5% volume loss. The aim of this study was to assess whether HPI can detect a 5% volume deficit and whether this is associated with a decrease in GI microvascular flow. Methods: Ten anesthetized, mechanically ventilated Yorkshire/Landrace crossbred pigs were studied. Hemorrhage was performed removing 1% aliquots of blood until 10% of blood volume was removed. Once complete, the removed blood was reinfused in 2% aliquots. Hemodynamic and intestinal microcirculatory measurements were performed at each stage. A repeated-measurement one-way ANOVA was used to compared changes from baseline measurements during hemorrhage and the final hemorrhage stage during reinfusion. Results: There was a significant change in MAP from baseline values at 3% hemorrhage with a 6.0 mm Hg decrease (95% confidence interval [CI], 0.2-11.8; P < 0.05) from 93 (3) mm Hg to 87 (4) mm Hg. HPI showed a significant rise from baseline values from 17 (6) to 44 (22) with a mean difference (MD) of 26.4 (95% CI, 2.1-50.7; P < 0.005) at 5% hemorrhage. For classifying if a model was greater than 5% volume deplete, the area under the curve for the analyzed variables was the following: HPI, 0.97 (95% CI, 0.90-0.98; P < 0.0001); stroke volume variation, 0.80 (95% CI, 0.73-0.89; P < 0.0001); and MAP, 0.90 (95% CI, 0.85-0.95; P < 0.0001). There were significant decreases in microcirculation scores comparing baseline with 1% hemorrhage (MD, -1.89; 95% CI, -2.49 to -1.29; P < 0.0001), 1% hemorrhage with 2% hemorrhage (MD, -1.90; 95% CI, -2.67 to -1.15; P < 0.0001), up to 4% hemorrhage compared with 5% (MD, -1.34; 95% CI, -2.31 to -0.37; P < 0.0001). Conclusion: Intestinal microcirculation is disrupted with minimal volume loss and is reduced by almost 75% at a blood loss of 5% volume. The reduction in GI MFI is not captured in clinically significant changes in commonly measured parameters but is reflected in changes in the HPI at 5% volume loss.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating that HPI flags occult hypovolemia harming gut flow before MAP falls; human trials needed before practice change.
No takes yet. Share an insight, caveat, or question.
Davies et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: