Why the study?
PIM-SRA is a novel approach for hypertrophic obstructive cardiomyopathy, but a large animal model to evaluate its safety, efficacy, and pathological changes was lacking.
Does percutaneous intramyocardial septal radiofrequency ablation safely reduce interventricular septal thickness in a healthy ovine model?
Does percutaneous intramyocardial septal radiofrequency ablation safely reduce interventricular septal thickness in a healthy ovine model?
In a healthy ovine model, percutaneous intramyocardial septal radiofrequency ablation safely and effectively reduced interventricular septal thickness without causing conduction system damage at 1 year.
Should not change HOCM practice; leaves open whether 1-year ovine septal thinning and conduction safety translate to patients.
BACKGROUND: Percutaneous intramyocardial (PIM) septal radiofrequency ablation (SRA) is a novel treatment approach for hypertrophic obstructive cardiomyopathy patients, but there has been lack of a large animal model to study PIM-SRA. We aimed to validate the long-term safety and efficacy of PIM-SRA and to observe pathological changes of the ablated interventricular septum (IVS) in a healthy sheep model. METHODS AND RESULTS: Twelve sheep were randomized to the PIM-SRA group (n = 6) and the sham group (n = 6). In the PIM-SRA group, a radiofrequency (RF) electrode was inserted into the IVS with a maximum power of 80 W for 5 min. In the sham group, the RF electrode tip was positioned in the IVS segment but without RF power delivery. Septal hypokinesis was seen in all PIM-SRA group animals immediately after the procedure; the systolic wall thickening rate and motion amplitude of the ablated region decreased (p < 0.01), and the diastolic IVS thickness also decreased significantly over time (p < 0.01). ECG showed that all the sheep had normal sinus rhythm during the follow-up. Pathological examinations revealed scar tissue in the ablated region as expected. CONCLUSIONS: PIM-SRA produced precisely ablated myocardial tissue, reduced the IVS thickness significantly, preserved the global LV function, and avoided the incidence of conduction system damage in the long term. PIM-SRA was found to be a safe and effective minimally invasive septal reduction therapy.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More on EchocardiographyMore from Cardiology