Why the study?
Does increasing the number of cine frames improve the accuracy of PC-MRI measurements of coronary artery flow compared to perivascular ultrasound?
Does increasing the number of cine frames improve the accuracy of PC-MRI measurements of coronary artery flow compared to perivascular ultrasound?
Increasing the number of cine frames in breath-hold PC-MRI improves the accuracy of coronary artery flow measurements when compared to perivascular ultrasound.
Answers are grounded in this paper and cite their sources.
More cine frames may improve PC-MRI coronary flow accuracy; leaves open prospective validation in patients.
Phase-contrast magnetic resonance imaging (PC-MRI) can be used to produce multiframe cine flow images of the coronary arteries. Accurate coronary flow measurement requires the elimination of respiratory motion artifacts using k-space segmentation to acquire the data in a single breath-hold. However, the duration of the breath-hold is proportional to the number of cine frames. In the present study, the number of cine frames was varied and the accuracies of the coronary flow measurements were assessed using perivascular US. For the range of flows studied (2 ml/min to 147 ml/min), the correlation coefficients for PC-MRI and US increased (.70-.98) and the limits of agreement improved (+/-45 ml.min-1 to +/-10 ml.min-1) as the number of cine frames increased from one to six. The results suggest that the accuracy of breath-hold cine PC-MRI measurements of coronary artery flow improves as the number of cine frames increases.
No takes yet. Share an insight, caveat, or question.
Clarke et al. (1996) studied this question.