Answers are grounded in this paper and cite their sources.
A 23-year-old male presented to us wanting spectacle removal for cosmetic purposes. He underwent bilateral wavefront optimized (WFO) laser-assisted in situ keratomileusis (LASIK) on the Alcon Wavelight® EX-500 excimer laser with an incorrectly treated astigmatism axis for left eye due to a manual data entry error in the laser. WFO LASIK treats the sphere and cylinder only. LASIK enhancement with topographic-guided ablation resulted in the elimination of all refractive errors and gave excellent results. Wavelight® topographic-guided treatment can perform two separate layers of correction in the same ablation: The first is to treat the corneal irregularities for the higher order aberration (HOA) removal, the second one meant to treat the sphere and cylinder if indicated.
No takes yet. Share an insight, caveat, or question.
Ahooja et al. (2020) studied this question.