Key result
Noble metal-coated catheters show no benefit over standard silicone catheters for CAUTI in stroke patients.
Cohort
Yes
Answers are grounded in this paper and cite their sources.
OBJECTIVE: Catheter-associated urinary tract infection (CAUTI) is the most common healthcare-associated infection. The primary aim of this study was to investigate whether the use of a silicone catheter coated with an ultrathin layer of a combination of the noble metals gold, palladium and silver (BIP™-silicone catheter) could reduce the incidence of CAUTI and antibiotic prescription compared with a standard silicone catheter in a cohort of acute neurological patients suffering primarily from stroke. At the same time, all infectious events requiring prescription of an antimicrobial agent were registered and are reported. MATERIALS AND METHODS: The study was designed as a crossover cohort study enrolling men and women aged over 18 years, requiring emergency management for stroke including the insertion of an indwelling catheter. Data on patient characteristics, urinary tract infections (UTIs), other infectious events and all antibiotic prescriptions were recorded prospectively. RESULTS: The patients' characteristics differed in the two centres in terms of age but not in diagnosis distribution. UTIs were recorded in 78 (24.2%) of the patients, ahead of pulmonary tract infections (n = 65; 20.2%). There was no difference in terms of CAUTI in the two catheter groups, even in subgroups with catheter treatment for 1 week or less. The patients with a diagnosed UTI required 3.5 more days of hospitalization than those without a UTI. CONCLUSION: CAUTIs were the most frequent healthcare-associated infections, slightly ahead of pulmonary tract infections. No advantages of the coated catheter could be found in this cohort of critically ill patients.
No takes yet. Share an insight, caveat, or question.
Stenzelius et al. (2016) conducted a cohort in Acute stroke requiring emergency management and indwelling catheterization. BIP-silicone catheter (coated with gold, palladium, and silver) vs. Standard silicone catheter was evaluated on Incidence of catheter-associated urinary tract infection (CAUTI) and antibiotic prescription. BIP-silicone catheters coated with noble metals showed no difference in CAUTI incidence compared with standard silicone catheters in acute stroke patients.
Synapse has enriched 10 related papers. Consider them for comparative context: