Key result
Salazar-Corcoran and Cockcroft-Gault best predict creatinine clearance, but all tested equations show poor precision.
Observational (n=420)
Yes
Answers are grounded in this paper and cite their sources.
Retrospective analysis reveals varying accuracy among ten creatinine clearance equations in cardiac patients, suggesting Salazar-Corcoran and Cockcroft-Gault formulas perform best.
OBJECTIVE: The predictive performance of 10 equations used to estimate creatinine clearance (Clcr) was assessed retrospectively from data collected on 420 patients. DESIGN: This study is a retrospective data analysis of information collected on hemodynamically stable patients awaiting coronary angiography during the Iohexol Cooperative Study. SETTING: The Iohexol Cooperative Study was a multicenter study that compared nephrotoxicity of high- and low-osmolar contrast media in patients undergoing coronary angiography. Data used for this analysis were preangiography 24-hour urine collections that were primarily collected in hospitalized patients. PATIENTS: Patients selected from the Iohexol Cooperative Study database for analysis were participants categorized into one or more of six subgroups: elderly (n = 222), hypoalbuminemic (n = 25), chronic renal insufficiency (n = 128), low serum creatinine (n = 115), obese (n = 208), and diabetic (n = 191) who had baseline urine collections of at least 24 hours. OUTCOME MEASURES: Predictive performance was assessed using bias, precision, slopes, and y-intercepts. RESULTS: The Salazar-Corcoran equation was unbiased in the entire group as well as in five of the subgroups. The Cockcroft-Gault equation was unbiased in three of the subgroups. All other equations were biased in predicting Clcr in the entire group as well as in at least four of the subgroups. Precision was generally poor. All slopes were significantly different than one and all y-intercepts were significantly different than zero (p < 0.01). Correlation coefficients were between 0.63 and 0.79 with the exceptions of the low serum creatinine subgroup (r values 0.35-0.64) and the Davis-Chandler equation (r values 0.35-0.71 across groups). CONCLUSIONS: Of the equations studied, Salazar-Corcoran and Cockcroft-Gault appear to be the best for predicting Clcr.
No takes yet. Share an insight, caveat, or question.
Spinler et al. (1998) conducted an observational in Hemodynamically stable cardiac patients awaiting coronary angiography (n=420). 10 creatinine clearance estimation equations (including Salazar-Corcoran and Cockcroft-Gault) vs. Preangiography 24-hour urine collection creatinine clearance was evaluated on Predictive performance for estimating creatinine clearance (bias, precision, slopes, and y-intercepts) (r 0.63-0.79, p=<0.01). The Salazar-Corcoran and Cockcroft-Gault equations best predicted creatinine clearance, though all 10 equations had poor precision and slopes/intercepts differing from ideal.
Synapse has enriched 10 related papers. Consider them for comparative context: