Key result
Blood in lung effluent abolishes downstream aortic relaxation during inhaled nitric oxide, reducing vasodilation to ~2%.
Answers are grounded in this paper and cite their sources.
BACKGROUND: Inhaled nitric oxide gas selectively decreases pulmonary artery pressure without affecting systemic arterial pressure. To determine if the selective pulmonary vasodilating effect of inhaled nitric oxide gas is due to inactivation by hemoglobin, we studied the ability of whole blood to inhibit the vasodilator activity of effluent from isolated lungs exposed to inhaled nitric oxide. METHODS AND RESULTS: The effluent from ventilated, Krebs-perfused rabbit lungs was passed directly over 3- to 4-mm rabbit aortic rings. Inhaled nitric oxide (150 ppm for 3 minutes) reduced pulmonary perfusion pressure, elevated by a continuous infusion of U46619, by 35 +/- 7% (mean +/- SEM, n = 5). Lung effluent from this series of experiments caused 40 +/- 13% relaxation of phenylephrine-preconstricted aortic rings. When blood was added to the combined lung/ring perfusion cascade (final hemoglobin concentration, 1 g/dL), inhaled nitric oxide again significantly reduced pulmonary perfusion pressure, but the effluent now failed to relax the aortic rings (30 +/- 6% [control] versus 1.5 +/- 1% [blood]). Both reduction in pulmonary perfusion pressure and relaxation of the rings during nitric oxide exposure were unchanged from control values after discontinuing the blood infusion. CONCLUSIONS: The presence of hemoglobin, even in extremely small amounts, restricts the vasodilating effect of inhaled nitric oxide gas to the pulmonary circulation.
No takes yet. Share an insight, caveat, or question.
Rimar et al. (1993) studied Elevated pulmonary perfusion pressure (preclinical rabbit lung/aortic ring model) (n=5). Inhaled nitric oxide with whole blood addition vs. Control perfusion without blood was evaluated on Relaxation of phenylephrine-preconstricted rabbit aortic rings by lung effluent. Adding whole blood (hemoglobin 1 g/dL) to lung effluent during inhaled nitric oxide exposure abolished downstream aortic ring relaxation while preserving pulmonary vasodilation.
Synapse has enriched 10 related papers. Consider them for comparative context: