Application of BioGlue at the atrio-caval junction can cause acute compression of the inferior vena cava, which resolves upon removal of the sealant.
Answers are grounded in this paper and cite their sources.
Alert to BioGlue as potential IVC compression cause in surgery; case report leaves open incidence and prevention studies.
We describe a case of 68-year-old woman which was admitted to our hospital for mitral valve replacement (MVR), in whom acute compression of the vena cava inferior developed after repair of lacerated atrio-caval junction with hemostatic tissue sealant, biologic glue (BioGlue, Cryolife, inc, Kennesaw, Ga). Removal of the BioGlue relieved the unexpected problem.
No takes yet. Share an insight, caveat, or question.
Çavolli et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: