Why the study?
While various quantitative markers exist to assess ventricular contractility, this study aims to compare the proficiency of NPE-experienced versus non-experienced providers in assessing cardiac contractility using qualitative and quantitative echocardiographic markers.
Does qualitative echocardiographic assessment by experienced and non-experienced operators accurately reflect cardiac contractility compared to quantitative markers in newborn infants?
Does qualitative echocardiographic assessment by experienced and non-experienced operators accurately reflect cardiac contractility compared to quantitative markers in newborn infants?
This study protocol outlines a prospective cohort study to evaluate the accuracy of qualitative versus quantitative echocardiographic markers for assessing cardiac contractility in newborns by operators with varying experience.
Qualitative newborn echo assessment accuracy remains uncertain across operators; this protocol will generate needed comparative data.
INTRODUCTION: Neonatologist-performed echocardiography (NPE) is increasingly used in the neonatal intensive care unit, aiding clinicians in enhancing diagnostic precision and guiding treatment decisions based on underlying pathophysiology. Experienced NPE operators typically use visual estimation of the cardiac contractility and if required confirm findings using quantitative echocardiographic markers.While various quantitative echocardiographic markers are available to assess left and right ventricular contractility, this study aims to compare the proficiency of NPE-experienced and non-experienced providers in accurately assessing cardiac contractility using a combination of commonly used qualitative and quantitative echocardiographic markers. METHODS AND ANALYSIS: Newborn infants, both inborn and outborn, undergoing routine NPE by the authors at Homerton University Hospital and Aberdeen Maternity Hospital from 1 April 2024 to 1 October 2024 will be studied. Indications for NPE include murmur evaluation, infants receiving intensive care and the need to assess underlying cardiovascular physiology.Blinded experienced and non-experienced NPE operators will independently assess left and right ventricular contractility using qualitative echocardiographic markers. The results will be compared with standard quantitative echocardiographic markers for cardiac contractility, and reliability studies will also be conducted for quantitative makers.Clinical data will be sourced from electronic patient records and national neonatal database. Sensitivity, specificity, positive predictive and negative predictive values, and positive and negative likelihood ratios will be calculated. ETHICS AND DISSEMINATION: The study is approved by the Health and Care Research Wales Research Ethics Committee and the Health Research Authority (HRA) (reference 23/HRA/3066). The study findings will be presented at national/international conferences and published in peer-reviewed scientific journals.
No takes yet. Share an insight, caveat, or question.
Pereira et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: