Key result
Two-dimensional speckle-tracking echocardiography in healthy infants showed that longitudinal and circumferential systolic velocity, strain, and strain rate decreased from base to apex (p<0.001).
Cross-Sectional (n=149)
p-value: p=<0.001
Tissue Doppler and speckle-tracking echocardiography can detect significant cardiac haemodynamic alterations during the newborn and early infancy periods, with strain values decreasing from base to apex.
Provides normative base-to-apex strain gradients in healthy infants; extends speckle-tracking knowledge but requires validation before clinical use.
OBJECTIVES: To evaluate cardiac maturational and haemodynamic alteration in healthy newborns and infants and determine reference values in this period using tissue Doppler, strain, and strain rate echocardiography. MATERIAL AND METHODS: The study included 149 healthy subjects. Babies from 1 day to 3 months were selected from the well-baby nursery department, and infants were selected from paediatric clinics during routine visits for health maintenance. Subjects were allocated to four groups: preterm (36-37 weeks, n = 32), term (≥ 38 weeks, n = 32), 1 month of age (n = 47), and 3 months of age (n = 38). Standard echocardiographic evaluations, pulsed wave Doppler, tissue Doppler echocardiography, strain, and strain rate studies were applied by the same person using a MyLab50 echo machine. Longitudinal and circumferential systolic strain and strain rate measurements were assessed by two-dimensional speckle-tracking echocardiography in all subjects. RESULTS: The longitudinal systolic velocity, strain, and strain rate values derived from left ventricle apical four-, three-, and two-chamber images, and circumferential systolic velocity, strain, and strain rate values derived from left ventricle short-axis images decreased from the base to the apex in all subjects (p < 0.001). CONCLUSION: Significant cardiac haemodynamic alterations occurred during the newborn and early infancy periods and were detected by tissue Doppler, strain, and strain rate echocardiography. Although two-dimensional speckle-tracking echocardiography is useful and can produce improved, reliable results in clinical practice, it has some limitations. Therefore, more studies on this issue are required.
No takes yet. Share an insight, caveat, or question.
Elkıran et al. (2013) conducted a cross-sectional in Healthy newborns and infants (n=149). Two-dimensional speckle-tracking echocardiography was evaluated on Longitudinal and circumferential systolic velocity, strain, and strain rate values (p=<0.001). Two-dimensional speckle-tracking echocardiography in healthy infants showed that longitudinal and circumferential systolic velocity, strain, and strain rate decreased from base to apex (p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: