In vitro study demonstrates enhanced crown retention from rougher titanium bases, indicating macroretention grooves reduce bond strength.
Background Two-piece hybrid abutment crowns (HACs) are CAD/CAM-fabricated implant restorations adhesively bonded to prefabricated titanium bases (Ti-bases). Since adhesive bond represents a potential weakness, methods to enhance long-term durability are being investigated. The aim of this in vitro study was to evaluate the influence of additional macroretention, specifically a circumferential groove, incorporated into polymer-infiltrated ceramic network (PICN) and zirconia crowns, and two Ti-base sandblasting protocols on adhesive bond strength of HACs. Methods Ninety Ti-bases, 45 zirconia and 45 PICN crowns were divided into six groups ( N = 15). Prior to conventional cementation (Panavia V5, Kuraray) of zirconia control group (Z1), Ti-bases and internal crown surfaces were sandblasted (Al₂O₃; 50 μm; 1.0 bar) and treated with MDP primer. In PICN control group (H1), Ti-bases were sandblasted identically and pretreated with Adiva M-Prime. Internal surfaces of PICN crowns were etched (5% hydrofluoric acid) and primed with Adiva C-Prime. In Z2 and H2, a circular groove in the internal crown surface was prepared as a macroretention in addition to conventional pretreatment as performed in Z1 and H1. Z3 and H3 were also conditioned conventionally, as in Z1 and H1, but Ti-bases were sandblasted with 250 μm at 2.0 bar. After sandblasting, surface roughness values (RV) of Ti-bases were measured. Following thermocycling, tensile shear test was performed, and failure mode was analysed. Mean values were compared using t-test. Results RV differed significantly between differently blasted Ti-bases ( p < 0.001). Both crown materials achieved significantly higher mean pull-off forces (Z1: 1085 N ± 79; H1 = 664 N ± 68) in control groups than in groups with macroretention (Z2: 1017 N ± 65; H2 = 438 N ± 48) (Z: p = 0.024, H: p < 0.001), and significantly lower pull-off forces than in groups with rougher Ti-bases (Z3: 1298 N ± 98, H3: 744 N ± 64) (Z: p < 0.001, H: p = 0.0023). Conclusions Increasing pressure and grit size during corundum blasting of Ti-bases can achieve higher pull-off force for zirconia and PICN crowns. Additional macroretention, at least in the form used here, offers no advantage regarding bond strength.
No takes yet. Share an insight, caveat, or question.
Grander et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: