Answers are grounded in this paper and cite their sources.
Dear Editor, Blood transfusions (BTs) are standard of care in paediatric care, performed in inpatient and daycare settings, yet they carry risks of adverse events and human errors. While some complications are unavoidable, many procedural and logistic errors can be mitigated through rigorous pre-transfusion checks. Rapid transfusions, especially in young children, can cause severe haemodynamic fluctuations and related complications. To prevent such outcomes, red blood cells (RBCs) are typically transfused at a rate of 4–5 mL/kg/h.[1] Despite a sound theoretical understanding, there are practical errors that frequently happen in this aspect of the duration of BT. Here, we discuss a case where a rapid BT occurred due to overlooking of the drop factor (DF) in an infusion pump setup, emphasizing the need for double-checking equipment and settings to ensure patient safety. A 2-year-old child with thalassemia was admitted for routine BT. After completing pre-BT checks, transfusion of 120 mL (15 mL/kg) leucoreduced RBC was initiated using a volumetric infusion pump set at 30 mL/h over 4 h. However, the transfusion was completed within 1.5 h, raising suspicions of equipment malfunction. Upon investigation, it was revealed that a conventional adult BT set with a DF of 20 gtt/mL had been mistakenly used instead of a micro drip intravenous (IV) set, which operates at 60 gtt/mL [Figure 1]. The child received an end-transfusion dose of IV furosemide to prevent fluid overload. Vital signs remained stable throughout and after the transfusion, and the child tolerated the procedure well, with no documented adverse events and was discharged after 12 h of observation.Figure 1: Display of a volumetric infusion pump with different drop factors (red arrow)Historically, healthcare professionals often calculated infusion rates and drops per minute using pen and paper, adjusting IV drip sets through roller clamps – an approach frequently associated with medication errors. The advent of electronic infusion pumps significantly reduced such errors.[2] However, this case illustrates how programming and equipment setup, particularly confirming the correct DF, are critical in paediatric BT to prevent rapid infusion errors. Although rare, the incorrect rate seen in this case is a significant potential error that highlights the need for vigilant monitoring when using smart infusion pumps. Despite these technological advancements, programming errors and equipment failure can still occur. The volume from IV tubing is delivered at a specific flow rate, known as the DF (gtt/mL). Identifying the type of IV tubing (micro or macro drip) is essential in calculating the drip rate accurately. Micro drip sets, often used in children for smaller volumes, have a DF of 60 gtt/mL, whereas macro drip tubing may have a DF of 10, 15 or 20 gtt/mL, depending on the set used. Selecting the correct tubing type is crucial, particularly in paediatric settings, where accuracy is paramount. Incorrect rate is an infrequent yet significant medication error related to smart infusion pumps.[3] After conducting a detailed root cause analysis, additional contributing factors identified included issues with equipment standardisation, inconsistent training and communication breakdowns amongst healthcare workers. To mitigate these risks and promote sustainable improvements, we implemented interventions such as updating the pre-BT checklist to include equipment details such as DF and introducing structured training modules. Raising awareness of this issue, standardising practices and providing proper training on the use of infusion equipment can prevent such errors and significantly enhance paediatric patient safety. Declaration of patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form, the legal guardian has given his consent for images and other clinical information to be reported in the journal. The guardian understands that names and initials will not be published and due efforts will be made to conceal patient identity, but anonymity cannot be guaranteed. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Aswanth et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: