Answers are grounded in this paper and cite their sources.
Antineutrophil cytoplasmic antibodies (ANCAs)1 are associated with small-vessel vasculitis (SVV), such as Wegener granulomatosis, microscopic polyangiitis, and Churg–Strauss syndrome (1). Indirect immunofluorescence (IIF) analyses can distinguish 2 major patterns: cytoplasmic and perinuclear. The cytoplasmic ANCA pattern is typically associated with antibodies to proteinase 3 (PR3), whereas the perinuclear ANCA pattern is typically associated with antibodies to myeloperoxidase (MPO). PR3 ANCAs are predominantly seen in patients with Wegener granulomatosis, whereas MPO ANCAs are predominantly seen in patients with microscopic polyangiitis(1)(2)(3). Studies that have addressed the clinical usefulness of specific enzyme immunoassays (EIAs) for PR3 and MPO for the diagnosis of SVV have used a single cutoff value. In this letter, we illustrate how the likelihood ratio (LR) for SVV depends on the titer of anti-PR3 or anti-MPO antibodies. Our calculations are based on a clinically well-defined group of 37 consecutive patients with newly diagnosed SVV (data collected over a 10-year period) and 285 consecutive control individuals with disease (data collected over 21 months) that a physician suspected to be a vasculitis. Patients suspected of or having a diagnosis for a gastrointestinal problem (e.g., inflammatory bowel disease) were excluded. The characteristics of the included patients have previously been described (4). One patient with antiphospholipid syndrome who had PR3 and MPO ANCAs was excluded because SVV could not be ruled out. Two of the control individuals with disease were excluded because no residual serum sample was available. IIF analysis was performed with ethanol-fixed human neutrophil preparations (INOVA Diagnostics). PR3 ANCAs and MPO ANCAs were measured in international units per milliliter with the Wieslab capture kit from Euro-Diagnostica, in units with the QUANTA Lite™ method from INOVA Diagnostics, and in units per milliliter with the EliA™ assay platform from Phadia. The recommended cutoffs were 5 IU/mL, 20 U, and 7 U/mL, respectively. Patients were considered to have tested positive if either the PR3 ANCA result or the MPO ANCA result was positive. We calculated the likelihoods and the LRs (likelihood of the patients with disease divided by likelihood of the control individuals) for different test-result intervals for each of the EIAs and for IIF. Table 1 summarizes the results. For the Wieslab capture kit, the LRs were 0.17, 5.1, 20, and 123 for 0–5 IU/mL, 5–7 IU/mL, 7–100 IU/mL, and >100 IU/mL, respectively. For the INOVA assay, the LRs were 0.14, 7.7, 58, and 116 for 0–14 U, 14–20 U, 20–100 U, and >100 U, respectively. For the Phadia assay, the LRs were 0.14, 5.1, 100, and 131 for 0–7 U/mL, 7–20 U/mL, 20–100 U/mL, and >100 U/mL, respectively. For IIF, the LRs were 0.13, 0.8, 8, and 10 for negative, 1:40, 1:80–1:320, and >1:320, respectively. Our data demonstrate that the LR for SVV increases with antibody concentration and that LRs for a positive test result are much higher for EIAs than for IIF. The lower LR observed with IIF is due to the lower specificity of this assay. For the INOVA EIA, a test result between 14 U and 20 U (which is below the cutoff) had an LR of 7.7, which indicates a moderate increase in pretest-to-posttest probability. Use of the manufacturer’s proposed cutoff produces more false-negative results with the Inova assay. The LR for a negative test result was between 0.1 and 0.2 for both the EIAs and the IIF assay, indicating a substantial, but modest, difference in pretest-to-posttest probability. The use of LRs for different test-result intervals allows test results with a very high difference in pretest-to-posttest probability (an LR >10 or <0.1) to be distinguished from test results with a moderate difference (an LR between 5 and 10 or between 0.1 and 0.2) in pretest-to-posttest probability. Overview of the LRs as a function of antibody concentration for 3 different EIAs (Wieslab capture kit from Euro-Diagnostica, QUANTA Lite™ from INOVA Diagnostics, and EliA™ from Phadia) and one IIF assay (INOVA). Overview of the LRs as a function of antibody concentration for 3 different EIAs (Wieslab capture kit from Euro-Diagnostica, QUANTA Lite™ from INOVA Diagnostics, and EliA™ from Phadia) and one IIF assay (INOVA). In conclusion, we have illustrated how the use of LRs for different test-result intervals can improve the clinical usefulness of EIA testing for SVV. Clinical laboratories might consider providing likelihood ratios for test-result intervals to improve clinical interpretation.
No takes yet. Share an insight, caveat, or question.
Vermeersch et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: