Answers are grounded in this paper and cite their sources.
Study of 18 cases of post-operative CS wound infection due to Atypical Mycobacterium (M. chelonae) were found in a single hospital over a six-month period. Though the contaminating source could not be identified, remedial control measures taken includes changing all the operative equipment, autoclave machine, air conditioners, exhaust fans of OT, linen and mattresses and solutions like betadine, savlon, spirit and also suture material replaced with new ones. Antibiotic protocols are changed and daily cleaning of OT with cetrimide solution and daily fumigation for one month. No further Atypical MB infective episode have occurred in the one and a half year since the study. Awareness of this ubiquitous opportunistic organism that is not easily eradicated from the hospital environment and strong suspicion of chronic post-operative wound infection, careful surveillance, detailed attention to disinfectant methods of medical devices and appropriate control measures are essential to prevent potential outbreaks.
No takes yet. Share an insight, caveat, or question.
Vijayalaxmi et al. (2016) studied this question.