Answers are grounded in this paper and cite their sources.
Experimental study reveals high ambient vapor pressure of triacetone triperoxide, indicating substantially greater volatility than TNT for chemical detection.
Using a GC headspace measurement technique, the vapor pressure of TATP was determined over the temperature range 12 to 60 °C. As a check on the experimental method, TNT vapor pressure was likewise computed. Values for TNT are in excellent agreement with previous published ones. For TATP the vapor pressure was found to be ~ 7 Pa at ambient conditions. This value translates to a factor of 10 4 more molecules of TATP in air than TNT at room temperature. The dependence of TATP vapor pressure on temperature can be described by the equation log 10 P (Pa)=19.791−5708/ T (K). Its heat of sublimation has been calculated as 109 kJ/mol.
No takes yet. Share an insight, caveat, or question.
Oxley et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: