Key result
Continuous wavelet transform (CWT) provides a graphic representation for quantitative analysis of heart sounds simultaneously in time and frequency, aiding in extracting clinically useful information.
Continuous wavelet transform offers a promising method for the visual and quantitative analysis of complex, non-stationary heart sounds and murmurs.
Answers are grounded in this paper and cite their sources.
May aid time-frequency heart sound analysis; leaves open prospective clinical validation before adoption.
Heart sounds and murmurs can be utilised more efficiently by medical doctors when they are displayed visually, rather than through a conventional stethoscope. Heart sounds and murmurs provide clinician with valuable diagnostic and prognostic information. Although heart sound analysis by auscultation is convenient as a clinical tool, heart sound signals are so complex and non-stationary that they have a great difficulty to analyse in time or frequency domain. The performance of the continuous wavelet transform (CWT) is discussed in this paper. This technique is a suitable technique to analyse such a signal. The work presented in the paper is a new approach. The results can be validated among themselves based on a comparison between the PCG signal 'normal' and the other 'pathological'. The spectro-temporal characteristics of the PCG signal will be used as reference for results of treatment of pathological PCG signals. It was also shown that the coefficients of the CWT give a graphic representation that provides a quantitative analysis simultaneously in time and frequency. It is therefore very helpful in extracting clinically useful information.
No takes yet. Share an insight, caveat, or question.
Debbal et al. (2015) studied Heart murmurs and pathological heart sounds. Continuous wavelet transform (CWT) vs. Conventional stethoscope / time or frequency domain analysis was evaluated on Extraction of clinically useful information from PCG signals. Continuous wavelet transform (CWT) provides a graphic representation for quantitative analysis of heart sounds simultaneously in time and frequency, aiding in extracting clinically useful information.
Synapse has enriched 10 related papers. Consider them for comparative context: