Key result
Multiplate analyser measurement was reproducible and precise, identifying 31.8% of acute stroke and TIA patients as aspirin resistant.
Why the study?
Does the Multiplate analyser provide reproducible and precise platelet function testing to determine aspirin responsiveness in stroke and TIA patients?
Observational (n=110)
Does the Multiplate analyser provide reproducible and precise platelet function testing to determine aspirin responsiveness in stroke and TIA patients?
The Multiplate analyser is a reproducible and precise tool for assessing platelet function, revealing that nearly one-third of acute stroke or TIA patients are resistant to aspirin.
Answers are grounded in this paper and cite their sources.
Supports Multiplate testing for aspirin resistance in stroke/TIA; hypothesis-generating and should not yet change practice.
BACKGROUND: Platelet responsiveness to aspirin in people with cerebrovascular disease is poorly understood. OBJECTIVES: To determine: (i) normal reference range, imprecision and reproducibility of the Multiplate instrument in healthy volunteers naive to aspirin; (ii) imprecision and reproducibility of the Multiplate instrument in acute stroke and transient ischaemic attack (TIA); (iii) the relationship between aspirin responsiveness and clinical outcome. MATERIALS AND METHODS: We evaluated platelet function response to three agonists [Adenosine Diphosphate (ADP), Arachidonic Acid (AA), Collagen (Col)] using the Mulitplate platelet function analyser in a two-phase pilot study. In phase 1, we recruited healthy volunteers to determine the normal reference range and imprecision of the Multiplate instrument. In phase 2, we assessed platelet function in acute stroke or TIA patients presenting to hospital. These patients were bled within 24 h of presentation and between 12 and 24 h after ≥75 mg dose of Aspirin. Patients were followed up to 1 yr to assess mortality and recurrent cardiovascular event. RESULTS: Overall, 29 healthy volunteers and 81 stroke/TIA patients were recruited. On assessing components of variance, Multiplate testing is reproducible and precise in volunteers and stroke/TIA patients. In stroke patients receiving aspirin, Bland-Altman plots show initial day 1 measurement provided a reliable measure of continuing response to aspirin at day 3. We defined one-third of patients as aspirin resistant [31.8% (95% CI: 22.1%-42.8%)] using cut off mean aggregation of ≥23.08% for AA and mean aggregation of ≥80.76% for ADP. CONCLUSION: The Multiplate device gives reproducible, precise results in volunteers and stroke/TIA patients.
No takes yet. Share an insight, caveat, or question.
Mannu et al. (2014) conducted an observational in Acute stroke and transient ischaemic attack (TIA) (n=110). Multiplate analyser measurement was evaluated on Aspirin resistance (95% CI 22.1-42.8). Multiplate analyser measurement was reproducible and precise, identifying 31.8% of acute stroke and TIA patients as aspirin resistant.
Synapse has enriched 10 related papers. Consider them for comparative context: