We propose a simple intrinsic Fabry-Perot interferometer (FPI) based on single-mode fiber, where a thin film is formed by arc discharge to serve as one mirror of the FPI cavity. The temperature and refractive-index (RI) characteristics of the proposed device are investigated. Experimental results show that the device can provide temperature-independent measurement of RI with a fringe-contrast sensitivity of ~72.59 dB/RIU (RI units). Meanwhile, it can also be used as a temperature sensor with a wavelength sensitivity of ~8 pm/°C. Therefore, the potential simultaneous measurement of RI and temperature could be realized by detecting the variations of fringe contrast and wavelength, respectively.