Key result
Open surgical extraction and epicardial pacing resolved a passive fixation RV lead perforation through the septum and LV wall occurring over 9 years post-implant, with 9 months of uneventful follow-up.
Why the study?
Late pacemaker lead perforation is rare and comparatively little has been written about risk factors.
Case Report (n=1)
No
Demonstrates that passive fixation pacemaker leads can cause very-late-phase cardiac perforation (>9 years post-implant) through the interventricular septum and left ventricular wall in patients with risk factors such as chronic steroid therapy, advanced age, and low BMI, requiring open surgical extraction and repair.
Answers are grounded in this paper and cite their sources.
Very late passive fixation lead perforation warrants clinical vigilance in high-risk patients; extends known latency but leaves open surveillance protocols.
Key Teaching Points•A case of very late lead perforation from the interventricular septum to the left ventricular side by a passive fixation lead in the very late phase is reported.•Late lead perforation is rarer and comparatively little has been written about risk factors.•The case is instructive for diagnosis and therapeutic strategy for very-late-phase lead perforation. •A case of very late lead perforation from the interventricular septum to the left ventricular side by a passive fixation lead in the very late phase is reported.•Late lead perforation is rarer and comparatively little has been written about risk factors.•The case is instructive for diagnosis and therapeutic strategy for very-late-phase lead perforation.
No takes yet. Share an insight, caveat, or question.
Higashimoto et al. (2023) conducted a case report in Very-late-phase pacemaker lead perforation of the interventricular septum and left ventricle (n=1). Open chest surgical extraction of pacemaker system, perforation site repair, and simultaneous epicardial lead implantation was evaluated on Successful surgical lead removal, perforation repair, and complication-free recovery. Open surgical extraction and epicardial pacing resolved a passive fixation RV lead perforation through the septum and LV wall occurring over 9 years post-implant, with 9 months of uneventful follow-up.