Key result
P-wave dispersion linked to ~11% higher odds of post-pacemaker AHRE per ms.
Why the study?
New-onset atrial high-rate episodes occur more frequently in patients with CIEDs than in the general population, prompting investigation of associated clinical factors including sinus rhythm P-wave dispersion.
Does baseline P-wave dispersion on a surface 12-lead ECG predict new-onset atrial high-rate episodes within 1 year in patients undergoing dual-chamber pacemaker implantation?
Cohort (n=101)
No
Does baseline P-wave dispersion on a surface 12-lead ECG predict new-onset atrial high-rate episodes within 1 year in patients undergoing dual-chamber pacemaker implantation?
Pre-implantation P-wave dispersion on a standard 12-lead ECG (cut-off 48 ms) is a simple, non-invasive independent predictor of new-onset atrial high-rate episodes within 1 year after dual-chamber pacemaker implantation.
P-wave dispersion may stratify atrial high-rate episode risk after pacemaker implantation; hypothesis-generating and requires prospective validation before practice change.
Background The incidence of new-onset atrial high-rate episode (AHRE) is higher among patients with cardiac implantable electronic devices (CIEDs) than in the general population. We sought to elucidate the clinical factors associated with AHRE in CIED patients, including P-wave dispersion (PWD) in sinus rhythm. Methods and Results In all, 101 patients with CIEDs newly implanted between 2010 and 2014 were included in the study. PWD was measured at the time of device implantation via a body-surface electrocardiogram. AHRE was defined as any episode of sustained atrial tachyarrhythmia (>170 beats/min) recorded in the device’s memory. Patients were divided into an AHRE (n=34) and non-AHRE (n=67) group based on the presence or absence of AHRE within 1 year of device implantation and compared. Mean (±SD) patient age was 75±11 years. A greater incidence of sick sinus syndrome (P=0.05) and longer PWD (62.6±13.1 vs. 38.2±13.9 ms; P<0.0001) were apparent in the AHRE than non-AHRE group. Multivariate analysis revealed that PWD was an independent predictor of new-onset AHRE (odds ratio 1.11; 95% confidence interval 1.06–1.17; P<0.0001). In logistic regression analysis, receiver-operating characteristic curve analysis (area under the curve 0.90; P<0.001) suggested the best cut-off value for PWD was 48 mm (sensitivity 73.8%, specificity 77.9%). Conclusions PWD is a simple but feasible predictor of new-onset AHRE in patients with CIEDs.
No takes yet. Share an insight, caveat, or question.
Nishinarita et al. (2021) conducted a cohort in Patients with newly implanted permanent dual-chamber (DDD) pacemakers for sick sinus syndrome or atrioventricular block (n=101). P-wave dispersion (PWD) on pre-implantation sinus rhythm 12-lead ECG vs. Lower P-wave dispersion / non-AHRE group was evaluated on New-onset atrial high-rate episode (AHRE >170 beats/min and >5 min) within 1 year of device implantation (OR 1.11, 95% CI 1.06-1.17, p=<0.0001). P-wave dispersion independently predicted new-onset atrial high-rate episodes within 1 year after dual-chamber pacemaker implantation (OR 1.11 per ms, 95% CI 1.06-1.17, P<0.0001).