In adults with TGA after the Mustard procedure, exercise capacity is not related to echocardiographic parameters of diastolic function, although NT-proBNP is associated with selected diastolic parameters.
Answers are grounded in this paper and cite their sources.
Standard diastolic echo parameters should not yet guide exercise assessment in post-Mustard TGA; leaves open NT-proBNP utility and mechanisms of limitation.
OBJECTIVES: To evaluate the relation of echocardiographic parameters of diastolic function, exercise capacity (expressed as peakVO(2)) and NT-proBNP in patients with transposition of the great arteries (TGA) and Mustard procedure. METHODS: Diastolic function was determined by measuring tricuspid flow velocities (Ea/Aa ratio), isovolumic relaxation time (IVRT), and deceleration time (DT). E/Ea ratios were calculated. For assessment of systolic function, CMR was applied. RESULTS: E/A (r = 0.07, p = 0.66), E/Ea medial (r = 0.03, p = 0.84), E/Ea lateral (r = -0.01, p = 0.92), IVRT (r = -0.13, p = 0.44), and DT (r = -0.05, p = 0.76) were not correlated with peakVO(2). NT-proBNP showed a significant correlation with IVRT (r = 0.44, p = 0.004) and Ea/Aa medial (r = -0.34, p = 0.025). No correlation was found between RV systolic function and peakVO(2) (r = 0.07, p = 0.63). CONCLUSIONS: Exercise capacity in patients with TGA and Mustard procedure is not related to echocardiographic parameters of diastolic function. NT-proBNP is associated with selected echocardiographic parameters of diastolic function.
No takes yet. Share an insight, caveat, or question.
Schaefer et al. (2010) studied this question.