Answers are grounded in this paper and cite their sources.
The implementation of direct stator flux orientation (DSFO) control for induction machines on a versatile Motorola 56000 digital signal processor (DSP) based system is described. Some practical aspects of implementing DSFO control, such as parameter identification, flux estimation, and rotor angular velocity estimation, are discussed. Experimental results are presented to show the performance of a DSFO-controlled induction machine drive. Comparison between DSFO and direct rotor flux orientation (DRFO) control shows that DSFO is superior to DRFO in the field weakening region.>
No takes yet. Share an insight, caveat, or question.
Xu et al. (1991) studied this question.