Key result
Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP MR-imaging provided comparable aortic diameter measurements at the sinuses of Valsalva (38.2 mm vs 38.3 mm, p=0.53), with 3D-Dixon showing fewer artifacts.
Why the study?
The accuracy and precision of 3D-Dixon compared with 2D-SSFP MR-imaging for assessing aortic diameter in Marfan patients had not been directly established.
Does respiratory-gated 3D-Dixon MRI provide comparable accuracy and precision to 2D-SSFP MRI and echocardiography for assessing aortic diameter in patients with Marfan syndrome?
Observational (n=47)
No
Does respiratory-gated 3D-Dixon MRI provide comparable accuracy and precision to 2D-SSFP MRI and echocardiography for assessing aortic diameter in patients with Marfan syndrome?
Respiratory-gated 3D-Dixon MRI provides accurate and precise aortic diameter measurements in Marfan patients comparable to 2D-SSFP, with the added benefits of fewer artifacts and the ability to perform orthogonal multiplanar reformations.
Answers are grounded in this paper and cite their sources.
3D-Dixon offers comparable aortic measurements with fewer artifacts in Marfan patients; leaves open prospective validation versus echocardiography before routine adoption.
OBJECTIVES: To compare the accuracy and precision of 3D-Dixon and 2D-SSFP MR-imaging for assessment of aortic diameter in Marfan patients. METHODS: This prospective single-center study investigated respiratory-gated 3D-Dixon and breath-hold 2D-SSFP non-contrast MR-imaging at 3 T in 47 Marfan patients (36.0 ± 13.2 years, 28♀,19♂). Two radiologists performed individual diameter measurements at five levels of the thoracic aorta and evaluated image quality on a four-grade scale (1 = poor, 4 = excellent) and artifacts (1 = severe, 4 = none). Aortic root diameters acquired by echocardiography served as a reference standard. Intraclass correlation coefficient, Bland-Altman analyses, F-test, t-test, and regression analyses were used to assess agreement between observers and methods. RESULTS: Greatest aortic diameters were observed at the level of the sinuses of Valsalva (SOV) for 3D-Dixon (38.2 ± 6.8 mm) and 2D-SSFP (38.3 ± 7.1 mm) (p = 0.53). Intra- and interobserver correlation of diameter measurements was excellent at all aortic levels for both 3D-Dixon (r = 0.94-0.99 and r = 0.94-0.98) and 2D-SSFP (r = 0.96-1.00 and r = 0.95-0.99). 3D-Dixon-derived and 2D-SSFP-derived diameter measurements at the level of the SOV revealed a strong correlation with echocardiographic measurements (r = 0.92, p < 0.001 and r = 0.93, p < 0.001, respectively). The estimated mean image quality at the level of SOV was higher for 2D-SSFP compared to that for 3D-Dixon (3.3 (95%-CI: 3.1-3.5) vs. 2.9 (95%-CI: 2.7-3.1)) (p < 0.001). Imaging artifacts were less at all aortic levels for 3D-Dixon compared to 2D-SSFP (3.4-3.8 vs. 2.8-3.1) (all p < 0.002). CONCLUSION: Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP MR-imaging provide accurate and precise aortic diameter measurements. We recommend 3D-Dixon imaging for monitoring of aortic diameter in Marfan patients due to fewer imaging artifacts and the possibility of orthogonal multiplanar reformations of the aortic root. KEY POINTS: • Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP imaging provide accurate and precise aortic diameter measurements in patients suffering from Marfan syndrome. • Imaging artifacts are stronger in 2D-SFFP imaging than in 3D-Dixon imaging. • We recommend 3D-Dixon imaging for monitoring of aortic diameter in Marfan patients due to fewer imaging artifacts and the possibility of orthogonal multiplanar reformations.
No takes yet. Share an insight, caveat, or question.
Warncke et al. (2022) conducted an observational in Marfan syndrome (n=47). 3D-Dixon MR-imaging vs. 2D-SSFP MR-imaging was evaluated on Aortic diameter at the sinuses of Valsalva (MD 0.1, p=0.53). Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP MR-imaging provided comparable aortic diameter measurements at the sinuses of Valsalva (38.2 mm vs 38.3 mm, p=0.53), with 3D-Dixon showing fewer artifacts.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: