Key result
Inner-to-inner vessel wall measurements in non-contrast MRA resulted in significantly smaller aortic diameters compared to outer-to-outer measurements (mean difference -6.2 mm) and showed closer agreement with echocardiography.
Why the study?
Aortic diameter measurements guide aortic root surgery in Marfan patients, but consensus is lacking on whether to include or exclude the aortic wall in MRA-derived measurements.
Does inner-to-inner measurement provide more reliable aortic diameters compared to outer-to-outer measurement in Marfan patients using non-contrast MRA?
Observational (n=40)
No
Does inner-to-inner measurement provide more reliable aortic diameters compared to outer-to-outer measurement in Marfan patients using non-contrast MRA?
Inner-to-inner vessel wall diameter measurements in non-contrast MRA provide more reliable and accurate aortic root diameters compared to outer-to-outer measurements in Marfan patients.
Answers are grounded in this paper and cite their sources.
May improve aortic diameter consistency between non-contrast MRA and echocardiography; leaves open effects on clinical management and outcomes.
Aortic diameter measurements play a crucial role for the indication of aortic root surgery in Marfan patients. However, for magnetic resonance angiography (MRA)-derived measurements, there is no consensus on whether the aortic wall should be included or excluded in the aortic diameter. The purpose of this retrospective study was to compare the reliability of non-contrast bright blood MRA aortic inner-to-inner and outer-to-outer edge measurements in patients with Marfan syndrome. Forty Marfan patients underwent ECG-gated balanced steady-state free-precession MRA of the aorta at 1.5 T. Two readers independently performed inner and outer measurements at different aortic levels. They rated the image quality of the delineation of both inner and outer vessel wall edges on a four-point scale. MRA-derived diameters of the sinuses of Valsalva were compared with echocardiography-derived diameters. Aortic vessel wall delineation score was rated higher at all levels for inner than for outer vessel walls (p < 0.001). Inter- and intraobserver variances of aortic measurements were smaller for inner-to-inner measurements at the sinuses of Valsalva, sinotubular junction and ascending aorta (p < 0.03). There was a difference of 1.1 ± 2.3 mm for inner MRA measurements (p = 0.014) and 6.9 ± 3.1 mm for outer MRA measurements (p < 0.001) when compared to echocardiographic leading-edge measurements. Inner-to-inner vessel wall diameter measurements in non-contrast bright blood MRA provide more reliable diameters when compared to outer-to-outer vessel wall measurements of the aortic root. Therefore, we propose to rely on inner rather than outer aortic wall measurements in non-contrast-MRA when monitoring aortic diameters in patients with Marfan syndrome.
No takes yet. Share an insight, caveat, or question.
Weinrich et al. (2020) conducted an observational in Marfan syndrome (n=40). Inner-to-inner vessel wall measurements vs. Outer-to-outer vessel wall measurements was evaluated on Aortic diameter at the sinuses of Valsalva (MD -6.2 mm, p=<0.001). Inner-to-inner vessel wall measurements in non-contrast MRA resulted in significantly smaller aortic diameters compared to outer-to-outer measurements (mean difference -6.2 mm) and showed closer agreement with echocardiography.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: