Answers are grounded in this paper and cite their sources.
A comparison of density measurements between cylindrical Langmuir probes, resonance fluorescence scattering and microwave methods is performed in a singly ionized barium plasma of a Q-device by varying the following parameters: 1) Density n: 3 × 10 8 cm −3 ≤ n ≤ 3 × 10 11 cm −3 ; 2) Plate temperature T p : 2100°K ≤ T p ≤ 2500°K; 3) Plate material: Re and W; 4) Magnetic field B: 2 kG ≤ B ≤ kG; 5) Mode of operation: Double and single ended operations; 6) Ion temperature T i down to about room temperature, keeping the electron temperature T e = T p ; 7) Degree of ionization γ: 0.1% ≤ γ ≤ 100%; 8) Probe dimensions. If the density n is evaluated by equating the extrapolated ion saturation current I s at the plasma potential V s to the random ion current, it is shown that this yields a reliable relative value of the plasma density, which is by a factor of about 2.5 higher than the most probable value.
No takes yet. Share an insight, caveat, or question.
Oordt et al. (1968) studied this question.