Key result
In vivo microvascular resistance is ~4-fold higher in 10-micron vessels than glass-tube models.
Answers are grounded in this paper and cite their sources.
Resistance to blood flow through peripheral vascular beds strongly influences cardiovascular function and transport to tissue. For a given vascular architecture, flow resistance is determined by the rheological behavior of blood flowing through microvessels. A new approach for calculating the contribution of blood rheology to microvascular flow resistance is presented. Morphology (diameter and length), flow velocity, hematocrit, and topological position were determined for all vessel segments (up to 913) of terminal microcirculatory networks in the rat mesentery by intravital microscopy. Flow velocity and hematocrit were also predicted from mathematical flow simulations, in which the assumed dependence of flow resistance on diameter, hematocrit, and shear rate was optimized to minimize the deviation between measured and predicted values. For microvessels with diameters below approximately 40 microns, the resulting flow resistances are markedly higher and show a stronger dependence on hematocrit than previously estimated from measurements of blood flow in narrow glass tubes. For example, flow resistance in 10-microns microvessels at normal hematocrit is found to exceed that of a corresponding glass tube by a factor of approximately 4. In separate experiments, flow resistance of microvascular networks was estimated from direct measurements of total pressure drop and volume flow, at systemic hematocrits intentionally varied from 0.08 to 0.68. The results agree closely with predictions based on the above-optimized resistance but not with predictions based on glass-tube data. The unexpectedly high flow resistance in small microvessels may be related to interactions between blood components and the inner vessel surface that do not occur in smooth-walled tubes.
No takes yet. Share an insight, caveat, or question.
Pries et al. (1994) studied Microvascular blood flow resistance in rat mesentery. In vivo microvascular flow resistance calculation via intravital microscopy and mathematical flow simulations vs. Predictions based on blood flow measurements in narrow glass tubes was evaluated on Microvascular flow resistance (Factor of ~4 higher in 10-micron microvessels vs glass tubes). In vivo microvascular modeling showed flow resistance in <40-micron vessels is markedly higher than in glass tubes, exceeding glass-tube estimates by ~4-fold in 10-micron vessels.
Synapse has enriched 10 related papers. Consider them for comparative context: