Answers are grounded in this paper and cite their sources.
A foodborne antibody array (FAbA) was developed as a rapid, inexpensive, and accurate detection to simultaneously detect Escherichia coli O157:H7 and Salmonella spp. using a custom-made chemiluminescent detector. We have optimized fabrication processes, selected the antibody concentrations, calibrated the signals to the pathogen amount, and minimized assay time. In comparison with ∼4 hours for ELISA, FAbA takes only 75 minutes to achieve relatively the same sensitivities (8 × 104 and 5 × 107 CFU/ml for E. coli and Salmonella, respectively). The FAbA was able to detect the pathogens in milk at the same detection limits as in the buffer.
No takes yet. Share an insight, caveat, or question.
Charlermroj et al. (2011) studied this question.