Why the study?
Does 3D speckle-tracking echocardiography accurately predict elevated left ventricular filling pressure compared to the E/E' ratio in patients with CAD and preserved LVEF?
Does 3D speckle-tracking echocardiography accurately predict elevated left ventricular filling pressure compared to the E/E' ratio in patients with CAD and preserved LVEF?
While 3D speckle-tracking echocardiography can predict elevated left ventricular filling pressure in CAD patients with preserved LVEF, it does not outperform the conventional E/E' ratio.
Answers are grounded in this paper and cite their sources.
Should not replace E/E' for LV filling pressure assessment in CAD; leaves open incremental value in prospective studies.
OBJECTIVES: The purpose of this study was to investigate the diagnostic value of 3-dimensional (3D) speckle-tracking echocardiography for estimating left ventricular filling pressure in patients with coronary artery disease (CAD) and a preserved left ventricular ejection fraction. METHODS: Altogether, 84 patients with CAD and 30 age- and sex-matched healthy control participants in sinus rhythm were recruited prospectively. All participants underwent conventional and 3D speckle-tracking echocardiography. Global strain values were automatically calculated by 3D speckle-tracking analysis. The left ventricular end-diastolic pressure (LVEDP) was determined invasively by left heart catheterization. Echocardiography and cardiac catheterization were performed within 24 hours. RESULTS: Compared with the controls, patients with CAD showed lower global longitudinal strain, global circumferential strain, global area strain, and global radial strain. Patients with CAD who had an elevated LVEDP had much lower levels of all 4 3D-speckle-tracking echocardiographic variables. Pearson correlation analysis revealed that the LVEDP correlated positively with the early transmitral flow velocity/early diastolic myocardial velocity (E/E') ratio, global longitudinal strain, global circumferential strain, and global area strain. It correlated negatively with global radial strain. Receiver operating characteristic curve analysis revealed that these 3D speckle-tracking echocardiographic indices could effectively predict elevated left ventricular filling pressure (LVEDP >15 mm Hg) in patients with CAD (areas under the curve: global longitudinal strain, 0.78; global radial strain, 0.77; global circumferential strain, 0.75; and global area strain, 0.74). These parameters, however, showed no advantages over the commonly used E/E' ratio (area under the curve, 0.84). CONCLUSIONS: Three-dimensional speckle-tracking echocardiography was a practical technique for predicting elevated left ventricular filling pressure, but it might not be superior to the commonly used E/E' ratio in patients with CAD who have a normal left ventricular ejection fraction.
No takes yet. Share an insight, caveat, or question.
Ma et al. (2015) studied this question.