Why the study?
Signal quality assessment is essential for biomedical signal processing, but non-linear methods evaluating concurrent electrocardiographic, seismocardiographic, and gyrocardiographic signals required evaluation.
Does a SPAR-based approach with machine learning classifiers accurately assess the quality of cardiovascular signals (ECG, SCG, GCG) in healthy subjects?
Does a SPAR-based approach with machine learning classifiers accurately assess the quality of cardiovascular signals (ECG, SCG, GCG) in healthy subjects?
A SPAR-based approach combined with machine learning classifiers, particularly Gradient Boosting, is a promising method for accurately assessing the quality of cardiovascular signals like ECG, SCG, and GCG.
May support ML-based cardiovascular signal quality research; leaves open clinical validation before practice adoption.
Signal quality assessment is essential for biomedical signal processing, analysis, and interpretation. Various methods exist, including averaged numerical values, thresholding, time- or frequency-domain analysis, and nonlinear approaches. The aim of this study was to evaluate the quality of electrocardiographic (ECG) signals, seismocardiographic signals (SCG), and gyrocardiograms (GCG) based on symmetric projection attractor reconstruction (SPAR) with Takens delay coordinates with fit five classifiers: random forest, gradient boosting, random forest XGB, and support vector machines (SVM) with various number of decision tree-based estimators (100–10,000) and various kernels (linear, radial base function, and polynomial), respectively. The analysis was carried out on a public dataset “Mechanocardiograms with ECG reference” containing 29 concurrent ECG, SCG, and GCG signal recordings. The highest values without SMOTE were observed for ECG signals, SVM with fourth order polynomial kernel (accuracy of 0.6897, PPV of 0.6019, sensitivity of 0.5306, and F1 score of 0.4952), and after applying SMOTE were observed for Gradient Boosting in ECG signal (200 estimators, accuracy 0.7500, PPV of 0.7747, sensitivity of 0.7500, and F2 score of 0.7747 respectively). These findings suggest that the SPAR-based approach is a promising method to accurately assess the quality of cardiovascular signals, including seismocardiograms and gyrocardiograms.
No takes yet. Share an insight, caveat, or question.
Sieciński et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: