BACKGROUND: Insulin resistance (IR) precedes type 2 diabetes, but tests used to detect it in clinical settings reported poor reproducibility. We assessed the reliability of the [(13)C]glucose breath test ((13)C-GBT) in a sample of subjects without diabetes. Repeatability of the test was compared with that of other IR surrogates derived from the fasting or oral glucose tolerance test (OGTT). SUBJECTS AND METHODS: Eighty-six healthy volunteers received an oral load of 75 g of glucose in 150 mL of water followed by 1.5 mg/kg of [U-(13)C]glucose in 50 mL of water. Breath and blood samples were collected at baseline and at 10, 20, 30, 60, 90, 120, 150, and 180 min following the glucose load; the same procedure was repeated within 1 week. The enrichment of breath (13)CO2 was measured by ratio mass spectrometry and expressed as percentage oxidized dose at a given time period. Intrasubject variability was assessed with Bland-Altman plots and coefficients of variation (CVs). RESULTS: The overall CV of the (13)C-GBT was 12.99±11.61%, compared with 18.42% of fasting insulin, 19.44% for homeostasis model assessment, 17.06% of the composite insulin sensitivity index, and 29.99% for insulin in the 2-h oral glucose tolerance test. The variability of the (13)C-GBT tended to be higher in lean (17.40%) than in overweight (10.17%) and obese (12.61%) individuals. CONCLUSIONS: The variability of the (13)C-GBT is lower than that of other IR surrogates, making it a reproducible method to estimate insulin sensitivity in overweight and obese adults without diabetes. Because the individuals did not have diabetes but were within a high range of insulin sensitivity, the test should have application in clinical and population-based studies, given the evidence for the utility and limitations of this surrogate.
No takes yet. Share an insight, caveat, or question.
Maldonado‐Hernández et al. (2014) conducted an observational in Insulin resistance in adults without diabetes (n=86). [13C]glucose breath test (13C-GBT) vs. Fasting insulin, homeostasis model assessment (HOMA), composite insulin sensitivity index, and 2-h OGTT insulin was evaluated on Intrasubject variability (coefficient of variation, CV) for estimating insulin resistance/sensitivity. The [13C]glucose breath test showed lower intrasubject variability than fasting insulin, HOMA, composite ISI, and 2-h OGTT insulin.
Synapse has enriched 10 related papers. Consider them for comparative context: