Purpose Computed tomography ventilation imaging derived from four‐dimensional cone beam CT (CTVI 4DCBCT ) can complement existing 4 DCT ‐based methods ( CTVI 4 DCT ) to track lung function changes over a course of lung cancer radiation therapy. However, the accuracy of CTVI 4 DCBCT needs to be assessed since anatomic 4 DCBCT has demonstrably poor image quality and small field of view ( FOV ) compared to treatment planning 4 DCT . We perform a direct comparison between short interval CTVI 4 DCBCT and CTVI 4 DCT pairs to understand the patient specific image quality factors affecting the intermodality CTVI reproducibility in the clinic. Methods and materials We analysed 51 pairs of 4 DCBCT and 4 DCT scans acquired within 1 day of each other for nine lung cancer patients. To assess the impact of image quality, CTVI s were derived from 4 DCBCT scans reconstructed using both standard Feldkamp‐Davis‐Kress backprojection ( ) and an iterative McKinnon‐Bates Simultaneous Algebraic Reconstruction Technique ( ). Also, the influence of FOV was assessed by deriving CTVI s from 4 DCT scans that were cropped to a similar FOV as the 4 DCBCT scans ( ), or uncropped ( ). All CTVIs were derived by performing deformable image registration (DIR) between the exhale and inhale phases and evaluating the Jacobian determinant of deformation. Reproducibility between corresponding CTVI 4 DCBCT and CTVI 4 DCT pairs was quantified using the voxel‐wise Spearman rank correlation and the Dice similarity coefficient ( DSC ) for ventilation defect regions (identified as the lower quartile of ventilation values). Mann – Whitney U‐tests were applied to determine statistical significance of each reconstruction and cropping condition. Results The (mean ± SD ) Spearman correlation between and was 0.60 ± 0.23 (range −0.03–0.88) and the DSC was 0.64 ± 0.12 (0.34–0.83). By comparison, correlations between and showed a small but statistically significant improvement with = 0.64 ± 0.20 (range 0.06–0.90, P = 0.03) and DSC = 0.66 ± 0.13 (0.31–0.87, P = 0.02). Intermodal correlations were noted to decrease with an increasing fraction of lung truncation in 4 DCBCT relative to 4 DCT , albeit not significantly (Pearson correlation R = 0.58, P = 0.002). Conclusions This study demonstrates that DIR based CTVI s derived from 4 DCBCT can exhibit reasonable to good voxel‐level agreement with CTVI s derived from 4 DCT . These correlations outperform previous cross‐modality comparisons between 4 DCT ‐based ventilation and nuclear medicine. The use of 4 DCBCT scans with iterative reconstruction and minimal lung truncation is recommended to ensure better reproducibility between 4 DCBCT ‐ and 4 DCT ‐based CTVI s.
No takes yet. Share an insight, caveat, or question.
Woodruff et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: