Why the study?
Does a standardized procedural protocol with X-ray disabled after transseptal puncture reduce fluoroscopy time and radiation dose in patients undergoing pulmonary vein isolation?
Does a standardized procedural protocol with X-ray disabled after transseptal puncture reduce fluoroscopy time and radiation dose in patients undergoing pulmonary vein isolation?
A standardized protocol disabling X-ray after transseptal puncture during PVI is feasible and significantly reduces fluoroscopy time and radiation exposure.
Answers are grounded in this paper and cite their sources.
May support low-fluoroscopy PVI protocols; leaves open randomized confirmation of safety and outcomes.
AIMS: It is recommended to keep exposure to ionizing radiation as low as reasonably achievable. The aim of this study was to determine whether fluoroscopy-free mapping and ablation using a standardized procedural protocol is feasible in patients undergoing pulmonary vein isolation (PVI). METHODS AND RESULTS: Sixty consecutive patients were analysed: Thirty consecutive patients undergoing PVI using Carto3 were treated using a standardized procedural fluoroscopy protocol with X-ray being disabled after transseptal puncture (Group 1) and compared with a set of previous 30 consecutive patients undergoing PVI without a specific recommendation regarding the use of fluoroscopy (Group 2). The main outcome measures were the feasibility of fluoroscopy-free mapping and ablation, total fluoroscopy time, total dose area product (DAP), and procedure time. Sixty patients (age 60 ± 10 years, 73% male, ejection fraction 0.55 ± 0.09, left atrium 42 ± 8 mm) were included. In Group 1, total fluoroscopy time was 4.2 (2.6-5.6) min and mapping and ablation during PVI without using fluoroscopy was feasible in 29 of 30 patients (97%). In Group 2, total fluoroscopy time was 9.3 (6.4-13.9) min (P < 0.001). Total DAP was 13.2 (6.2-22.2) Gy*cm(2) in Group 1 compared with 17.5 (11.7-29.7) Gy*cm(2) in Group 2 (P = 0.036). Total procedure time did not differ between Groups 1 (133 ± 37 min) and 2 (134 ± 37 min, P = 0.884). CONCLUSION: Performing mapping and ablation guided by an electroanatomic-mapping system during PVI without using fluoroscopy after transseptal puncture using a standardized procedural protocol is feasible in almost all patients and is associated with markedly decreased total fluoroscopy duration and DAP.
No takes yet. Share an insight, caveat, or question.
Knecht et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: