In this paper, manufacturing technology of the tubular single lap adhesive joint was studied to obtain reliable and optimal joint quality. In addition, a surface preparation method and a bonding process for the joint were devised. The effect of the adhesive thickness and the adherend roughness on the fatigue strength of the joint was experimentally investigated. From experiments, it has been found that the fatigue strength of the joint increased as the adhesive thickness decreased and the optimal arithmetic surface roughness of the adherends was about 2 μm.
No takes yet. Share an insight, caveat, or question.
Lee et al. (1991) studied this question.