Why the study?
Can direct millimeter measurement reliably predict NASCET, ECST, and CSI percentage stenoses in patients undergoing carotid CT angiography?
Can direct millimeter measurement reliably predict NASCET, ECST, and CSI percentage stenoses in patients undergoing carotid CT angiography?
Direct millimeter measurement of carotid stenosis on CT angiography strongly correlates with established percentage-based methods and may reduce discrepancies associated with ratio-percent calculations.
May simplify carotid stenosis grading on CTA; leaves open prospective outcome validation before practice change.
PURPOSE: The purpose of this study was to compare 3 percentage carotid artery measurement methods (the North American Symptomatic Carotid Endarterectomy Trial [NASCET], the European Carotid Surgery Trial [ECST], and the Carotid Stenosis Index [CSI]) and 1 millimeter method (direct millimeter measurement) to evaluate the difference and correlation between them. MATERIALS AND METHODS: Seven hundred ninety-two patients (591 men; age: mean, 63 years; range, 32-91 years) studied by using a multi-detector row computed tomographic scanner for a total of 1584 carotid arteries were retrospectively analyzed. Each carotid stenosis was measured according to 4 measurement methods (the NASCET, the ECST, the CSI, and the direct millimeter measurement). Carotid arteries with near-occlusion condition were excluded. The Kolmogorov-Smirnov Z test was used to test the normality of continuous variable groups. Comparison of derived ratio-percent methods was performed by using the Bland-Altman plots, and receiver operating characteristic curves were calculated. Correlation coefficients were also calculated by using a nonparametric Spearman correlation. A P < 0.05 was considered to mean statistical significance. RESULTS: Four hundred sixteen carotid arteries were excluded, and in the remaining 1168 ones, a strength correlation according to quadratic regression between the NASCET and ECST methods was observed (Spearman rho coefficient, 0.948; P < 0.0001). An inverse correlation according to linear regression was observed between the NASCET and the direct millimeter measurement (Spearman rho coefficient, -0.972; P < 0.0001); the CSI shows a quadratic regression with the NASCET, a linear regression with the ECST, and an inverse linear regression with the direct millimeter measurement (Spearman rho coefficient, 0.946, 0.932, and -0.939 respectively). The cutoff values for 50% and 70% NASCET stenosis were 2.36 and 1.51, respectively. CONCLUSIONS: Our study results indicate that the direct millimeter measurement of stenosis, by using appropriate equations, can reliably predict NASCET-, ECST-, and CSI-type percent stenoses. The use of direct millimeter measurement may remove the pitfalls and the discrepancies deriving from the use of different ratio-percent methods.
No takes yet. Share an insight, caveat, or question.
Saba et al. (2010) studied this question.