Why the study?
Patients with post-infarct cardiomyopathy and ventricular arrhythmias requiring ICDs are at risk of recurrent shocks with increased morbidity.
Does preventive catheter ablation reduce appropriate device therapies in patients with post-infarct cardiomyopathy undergoing secondary prevention ICD implantation?
Does preventive catheter ablation reduce appropriate device therapies in patients with post-infarct cardiomyopathy undergoing secondary prevention ICD implantation?
Preventive catheter ablation at the time of secondary prevention ICD implantation in patients with post-infarct cardiomyopathy significantly reduces appropriate ICD therapies and sustained VT, and improves physical quality of life, but does not reduce mortality.
Supports preventive ablation at secondary prevention ICD implantation in post-infarct cardiomyopathy; confirms benefit on therapies across trials.
BACKGROUND: Patients with post-infarct cardiomyopathy and ventricular arrhythmias (VT) necessitating implantable cardioverter defibrillators (ICD) are at risk of recurrent shocks with increased morbidity. METHODS: A comprehensive search of electronic databases for all randomized clinical trials that evaluated the role of catheter ablation as a preventive strategy at the time of secondary prevention ICD implantation was performed. We calculated hazard ratios (HR) and 95% confidence intervals (CI) using random-effects model. RESULTS: Four trials were identified with a total of 505 patients (average age 66.4 ± 9.0 years; 87.7% were male). Preventive ablation was associated with a significant reduction in appropriate device therapies (shocks and/or anti-tachycardia therapy) (HR = 0.62; 95% CI = 0.46-0.82; P < .01), sustained VT (HR = 0.74; 95% CI = 0.55-0.99; P = .04) compared to control. There were no differences in inappropriate device shocks (HR = 0.80; 95% CI = 0.38-1.71), all-cause death (HR = 0.93; 95% CI = 0.53-1.64), cardiac death (HR = 0.63; 95% CI = 0.29-1.36), arrhythmic death (HR = 0.26; 95% CI = 0.05-1.31), or cardiac hospitalization (HR = 0.79; 95% CI = 0.57-1.11) between strategies. Preventive ablation was associated with improved SF-36 physical component (mean difference = 2.81; 95% CI-0.53-5.10; P = .02), but not the mental component (mean difference = 1.30; 95% CI = -2.06-4.66). CONCLUSION: Among patients with post-infarct cardiomyopathy and VT, preventive catheter ablation at the time of ICD implantation is associated with a significant reduction of appropriate ICD therapy and sustained VT, and improvement in the physical component of quality-of-life, but no reduction in mortality.
No takes yet. Share an insight, caveat, or question.
Kheiri et al. (2020) studied this question.