Answers are grounded in this paper and cite their sources.
Research was performed to increase the efficiency of a plasma reactor for the H 2 yield. Ni as a transitional metal catalyst and TiO 2 as a photocatalyst were utilized for the generation of H 2 from an aqueous solution. The composition of aqueous solution, discharge properties and electrode geometry affected H 2 generation. It was found that the hollow type electrode configuration allowed discharge distribution along the perimeter of the electrode's tip, which increased the density of streamers and reduced plasma energy loadings, as the value of the inception voltage for the discharge propagation decreased. The maximum H 2 yield was observed at 2 kHz of discharge frequency and 12 kV of applied voltage, using distilled water, which was in compliance with a steep increase in electron density, n e ≈ 10 17 cm −3 and electron temperature, T e ≈ 2 eV. Within this favourable discharge condition, the synergistic effect of a non-thermal plasma and TiO 2 , Ni catalysts was investigated. The plasma state was studied by optical emission spectroscopy (OES), electrical and acoustical techniques. Emitted light, electric current and acoustical signals acquired from the discharge demonstrated systematical correlation. OES was used to estimate n e and T e by measuring the Stark broadening of the Balmer H β line and emission of H α and H β lines ratio, respectively. The rotational and vibrational temperatures were deduced from OH( A 2 Σ + – X 2 Π, Δυ = 0) and N 2 ( C 3 Π u – B 3 Π g ) bands.
No takes yet. Share an insight, caveat, or question.
Kostyuk et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: