Answers are grounded in this paper and cite their sources.
In conventional voltage control of grid-forming (GFM) inverter, the load current feedforward is often employed to reshape the output impedance and improve control performance. To further enhance this capability, an approximate zero-impedance control for three-phase GFM inverter is proposed in this paper. The core idea is to achieve zero impedance in the continuous domain by introducing a differential term into the load current feedforward path. A discrete-time optimal control (DTOC)-based tracking differentiator (TD) is utilized its excellent noise-suppression characteristics. The proposed approach is general-purpose and applicable across various control structures (e.g., conventional dual-loop or state-space) and reference frames (dqorαβ). Owing to the unique features of the method, the state-feedback parameters become decoupled from the impedance design, which significantly simplifies controller tuning. Finally, experimental results verify the effectiveness and robustness of the proposed strategy.
No takes yet. Share an insight, caveat, or question.
Du et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: