We present the design of a novel, ultralow-phase-noise frequency synthesizer implemented with extremely-low-noise regenerative frequency dividers. This synthesizer generates eight outputs, viz. 1.6 GHz, 320 MHz, 160 MHz, 80 MHz, 40 MHz, 20 MHz, 10 MHz and 5 MHz for an 8 GHz input frequency. The residual single-sideband (SSB) phase noises of the synthesizer at 5 and 10 MHz outputs at 1 Hz offset from the carrier are -150 and -145 dBc/Hz, respectively, which are unprecedented phase noise levels. We also report the lowest values of phase noise to date for 5 and 10 MHz RF signals achieved with our synthesizer by dividing an 8 GHz signal generated from an ultra-stable optical-comb-based frequency division. The absolute SSB phase noises achieved for 5 and 10 MHz signals at 1 Hz offset are -150 and -143 dBc/Hz, respectively; at 100 kHz offset, they are -177 and -174 dBc/Hz, respectively. The phase noise of the 5 MHz signal corresponds to a frequency stability of approximately 7.6 × 10(-15) at 1 s averaging time for a measurement bandwidth (BW) of 500 Hz, and the integrated timing jitter over 100 kHz BW is 20 fs.
No takes yet. Share an insight, caveat, or question.
Hati et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: