Why the study?
Does the extended vertical trans-septal approach (EVTSA) improve procedural outcomes and safety compared to the traditional left atrial approach in patients undergoing isolated primary mitral valve surgery?
Does the extended vertical trans-septal approach (EVTSA) improve procedural outcomes and safety compared to the traditional left atrial approach in patients undergoing isolated primary mitral valve surgery?
The extended vertical trans-septal approach is a safe and reproducible alternative to the traditional left atrial approach for mitral valve surgery, with comparable procedural times and complication rates.
Answers are grounded in this paper and cite their sources.
Supports EVTSA as safe alternative in mitral surgery; leaves open superiority in randomized trials.
OBJECTIVE: The mitral valve may be accessed directly through the left atrium but visualisation can sometimes be challenging. A trans-septal interatrial approach provides better exposure and easy access for concomitant tricuspid procedures especially in difficult cases. This retrospective study evaluates the safety and effectiveness of the extended vertical trans-septal approach (EVTSA) for routine mitral valve exposure. METHOD: 1017 consecutive patients undergoing an isolated primary mitral valve procedure (repair/replacement) through a median sternotomy were retrospectively studied between 2000 and 2015. Up to 135 patients were operated by EVTSA (group A) while 882 patients underwent a traditional left atrial (LA, group B) approach. RESULTS: There were 135 patients (M/F=56/79) in group A and 882 patients (M/F=398/484) in group B. Logistic EuroSCORE was significantly lower in EVTSA group (0.61 vs 0.90, p=0.000001). In the LA group there were more patients with preoperative transient ischaemic attack or stroke (94 vs 6, p=0.005). Cumulative cross-clamp time was 82 (44-212) min (EVTSA group) and 78 (30-360) min (LA group) (p=0.271) while cardiopulmonary bypass time was 107 (58-290) and 114 (43-602) min, respectively (p=0.121).Postoperative blood loss was 415 mL (EVTSA) vs 427 mL (LA) (p=0.273). No significant difference was found in the incidence of postoperative atrial fibrillation (p=0.22) or heart block requiring permanent pacemaker (p=0.14). CONCLUSION: In our opinion, EVTSA to the mitral valve is safe and reproducible. It gives excellent exposure of the mitral valve under all circumstances without any significant increase in cross-clamp or bypass time, postoperative arrhythmia, heart block/pacemaker rate or bleeding.
No takes yet. Share an insight, caveat, or question.
Mujtaba et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: